Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Use Of Accessories; Installation Of Photocell Spc - Schartec Jet 500 Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Installation and Use of Accessories

5.1. Installation of Photocell SPC

The Photocell SPC serves as additional safety device for gate openers. It consists of a transmitter and a receiver
and reacts when the light beam is interrupted.
SPECIFICATION:
Detection Method
Sensing Range
Input Voltage
Response Time
Emitting Element
Operation Indicator
Dimensions
Output Method
Current Consumption Max
Water Proof
INSTALLATION:
Connection the Photocells
TX: Connect terminals 1, 2 to terminals Ph+ and GND on the motherboard.
RX: Connect terminals 1, 2 to Ph+ and GND, connect 5 to Ph1 on the motherboard. Use an extra wire to
connect terminals 2 and 4 on the RX as a bridge, then with another wire connect terminal 4 to GND.
1
2
3
4
5
RX
Through Beam
up to 25 Meter
AC/DC 12~24V
100MS
IR LED
Red LED(RX) = ON (When Beam is Broken), Green(TX) = active
96*45*43mm
Relay Output
TX: 35MA / Rx: 38MA (When beam is aligned properly)
TX: 35MA / Rx: 20MA (When beam is broken)
IP54
Lens
Beam Alignment
Indicator
Power LED
Indicator
Terminal Block
Power Terminal
Block
14
13
1
2
COM
TX
34
12
11
10
9
8
7
PH+ PH2 PH1 GND
N.C.
N.O.
GND
DC+
RX
6
5
4
3
GND
DC+
TX

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Jet 800

Inhaltsverzeichnis