LED Display
"-L": The system learning is not completed.
"OP": The system is in normal operation. To enter
the menu, press "SET" for 3 seconds. The
display changes from OP to 1. Press "UP" and
"DOWN" to switch between the menu items (1 to
P). With "SET" you reach the respective
submenu and can also navigate here with "UP"
and "DOWN". Again, "SET" confirms the
selection in the menu.
Setting the power cut-off (over current) (Menu option 7 in display)
ATTENTION: The power cut-off is already set automatically during the learning run. An adjustment via the menu is
usually not necessary.
The factory-set forces (value 7-30) are designed to provide a smooth operation of the opener with standard sliding
gates; the factory setting forces should be, in principle, sufficient to fully open and close the gate. The factory setting
of the operator complies with the legal or relevant standards (such as the EN 13241-1, EN 12453, EN 60335-2-95)
established requirements for operational forces, and thus the maximum allowable power limits. If necessary, the
operating force of the operator may be increased or decreased (values 7-01 to 7-60) by the following procedure
described below.
NOTE
This must be done, for example, if one of the end positions "gate open" or "gate closed" is not reached via the
factory setting (value 7-30). Then, the setting for the maximum force, as described below, may be gradually
increased until both end positions are reached.
In addition, during the operational period of the gate, the operational optimality may deteriorate. Therefore, for
safety reasons, adjusting force of the operator on an unsound gate could result in a malfunctioning gate, thus
increasing the risk of personal injury or property damage -- this risk is especially increased when activating the
manual release of the gate from the operator.
DANGER
Deviating/Increasing the factory force setting (value 7-30) can lead to serious personal injury, up to the danger of life
as well as property damage! Altering the factory force setting increases the pressure exerted by the operator when
opening and closing gate, thus increasing the force that the gate exerts in each respective phase. When changing
or differing from the factory settings, the risk of severe injury to persons up to the danger of life as well as the risk of
damage to property is increased - for example, by pinching or squeezing persons or things near the gate. Differing
from the factory settings, increasing the power setting to exceed the aforementioned maximum allowable limit can
cause power limitations. Therefore:
NOTE:
After each setting of the force (values 7-01 to 7-60) deviating from the factory setting (value 7-30),
compliance with the force limit values required by law or in the relevant standards must be checked,
accepted, measured and documented by a qualified person to exclude the aforementioned dangers to life
and limb and property damage.
Photocell as additional safety device
In order to ensure safe operation of the gate system, it is absolutely necessary to install and activate the supplied
photocell safety beam and keep it activated. Operation without a photocell can lead to serious injuries to persons
and animals, even to life, as well as damage to property.
Function
LED Display
"LE": The system is in learning mode.
"LP": system is in the learning phase.
Opens and closes automatically. Then the
necessary forces are learned.
"CL": Reset to factory settings.