2.5 Check before Installation
SX
2.6 Emergency Manual Release
In the event of a power failure, please follow the procedure below to
manually release the motor.
Step 1. Slide the lid of release chamber to the right.
Step 2. Insert the key and turn counterclockwise to unlock the
device.
Step 3. Turn the bar counter-clockwise until it clicks in place to
release the motor.
To restore the automation, simply reverse the above procedure.
Step 1
DX
NO
Step 2
26
OK
Step 3