Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher A 1001 Bedienungsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Commissioning and
operation
Check the contents of the appliance for
completeness when unpacking. In the event
of missing parts or any transport damage,
inform your dealer immediately. Before you
can use the appliance, point
be observed.
Mount wheels/guide roller
Put motor casing onto container and lock
it.
Mount suction hose connection.
The suction hose connection remains at
the appliance after the assembly.
Connect accessories.
!
Never work without foam filter!
Only use dry foam filter!
Plug in mains cable / switch on appliance
Dry vacuum cleaning: Use a paper filter
bag.
Wet vacuum cleaning: Do not use any
paper filter bag!
Switch off immediately the appliance
!
with foam, liquid escape or with full
container!
Application examples for the accessory
Finish operation
– Empty the container
Rinse inside and let it dry, if necessary.
– Clean the appliance and accessory.
Do not clean the appliance with a hose
!
or high-pressure water jet.
– Store the appliance in dry rooms.
Care / Maintenance
!
Before any care and maintenance work
on the machine draw out the mains plug.
4
Technical data
Rated voltage
Fuse protection (surge-proof)
Container volume
Water uptake
Fan data:
to
must
P
max
P
nom
Weight
Class of protection
Mains cable type, H05VV-F2x0.75
Noise pressure level (DIN 45635)
We reserve the right to introduce
technical changes without prior notice.
Circuit diagram
C1
M1
S1
X1
EU Declaration of
Conformity
We hereby declare that the equipment described below conforms
to the relevant fundamental safety and health requirements of the
appropriate EU Directives, both in its basic design and
construction as well as in the version marketed by us.
This declaration will cease to be valid if any modifications are
made to the machine without our express approval.
Product:Wet & dry vacuum cleaner
Relevant EU Directives:
98/37/EG
73/23/EWG, (+ 93/ 68/EWG)
89/336/EWG, (+ 91/263/EWG, 92/31/EWG, 93/68 EWG)
Harmonised standards applied:
DIN EN 60 335 – 1
DIN EN 60 335 – 2 – 2
DIN EN 55 014 – 1 : 2000 + A1: 2001
DIN EN 55 014 – 2 : 1997
DIN EN 61 000 – 3 – 2 : 2000
DIN EN 61 000 – 3 – 3 : 1995 + A1: 2001
National standards applied: –
Appropriate internal measures have been taken to ensure that
series-production units conform at all times to the requirements
of current EU Directives and relevant standards.
The signatories are empowered to represent and act on behalf
of the company management.
Alfred Kärcher GmbH & Co. KG
Cleaning Systems
Alfred-Kärcher-Str. 28-40
P.O. Box 160
D-71349 Winnenden
Capacitor
Suction turbine
Switch
Plug
220–240 V
1~ 50, 60 Hz
10 A
10 l
4 l
1200 W
1000 W
3,7 kg
II
4 m
74 dB(A)
Typ: 1.293-xxx
ENGLISH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis