Error
Low ice production.
Machine works but does not
produce ice.
Ice is wet.
Very loud.
32
Cause
Insufficient water in the coo-
ling circuit.
Cooling water is too warm.
Water supply hose blocked.
Worn gears
No´water for the ice produc-
tion.
Room temperature is too
high.
Too much coolant in the
system.
Too much water in the ice
tray.
Faulty compressor.
Faulty ball bearings.
EN
Remedy/comments
Increase flow quantity.
Reduce water temperature.
Replace the water supply
hose.
Contact customer service.
Ensure a supply of water for
the ice production.
Position the flake ice machine
in a cool place.
Contact customer service.
Check water drain.
Contact customer service.
Contact customer service.
Contact customer service.