Malfunctions

If a malfunction occurs that you cannot remedy, please contact the customer service. The contact
data is stated in the service address.
Error
Flake ice machine does not
work.
Orange LED shines although
there is not ice in the ice tray.
The upper red LED shines.
The middle red LED shines.
Lowest red LED flashes.
Lowest red LED shines.
Compressor works irregularly.
Cause
Mains plug not in
Machine outside the set ope-
rating time.
Filling level sensor faulty.
No cooling
No´water for the ice produc-
tion.
No cooling
Pressure is too high.
Room temperature is too low
Evaporation temperature is
too high.
Screw turns in wrong direc-
tion.
Rotational speed of the screw
is too low.
Low voltage.
Gas that cannot condense in
the system.
Faulty compressor cable.
EN
Remedy/comments
Plug in to the mains
Set operating time correctly
(see section 'Set time con-
trol').
Clean filling level sensor or
arrange for it to be replaced
by a specialist.
Check the supply line to the
cooling system.
Check water supply.
Check the supply line to the
cooling system.
Contact customer service.
Regulate room temperature
Check the feed and return
lines of the cooling system.
Contact customer service.
Check ball bearings.
Contact customer service.
An electrician should check
the power circuit for overload.
Check power supply.
Contact customer service.
Contact customer service.