Herunterladen Inhalt Inhalt Diese Seite drucken

Setup And Drive Operation - Masterflex 77410-10 Betriebsanleitung

Pumpenantriebe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22

SETUP AND DRIVE OPERATION

1. Attach any external control connections. (Model 77411-00 only)
2. Mount Pump Head and load tubing (see Pump Head manual).
NOTE:
The High-Performance I/P pump is mounted with the tubing to the left. The Standard I/P pump is mounted
with the tubing up. The EASY-LOAD I/P pump is mounted with the occlusion bed up.
3. Turn drive on.
4. Select INTernal or EXTernal operation. (Model 77411-00 only)
5. Select pump DIRection (clockwise or counter-clockwise).
6. Press STOP/START key to begin pumping.
7. Adjust speed (listed flow rates are for reference only. Flow will vary with pressure, tubing, viscosity, and time):
Speed Setting
I/P 26
0.4 LPM
10%
0.11 GPM
0.8 LPM
20%
0.22 GPM
1.2 LPM
30%
0.33 GPM
1.6 LPM
40%
0.44 GPM
2.0 LPM
50%
0.55 GPM
2.4 LPM
60%
0.66 GPM
2.8 LPM
70%
0.77 GPM
3.2 LPM
80%
0.88 GPM
3.6 LPM
90%
0.99 GPM
4 LPM
100%
1.1 GPM
NOTE:
While in INTernal mode, drive will automatically restart after a brownout or power out condition unless
operator changes default setting. If speed is being controlled by an external signal, drive will automatically
restart with a non-zero speed command.
AUTOMATIC START ON/OFF (Internal mode only)
Press and hold DIR on power-up. After five (5) seconds, display will read "ON" (factory default) or "OFF". Hold the
DIR key for an additional 3 seconds and the display will toggle to the other option every 3 seconds. Release the DIR
key when the desired mode is being displayed. After releasing the key, "ON" or "OFF" will remain displayed
for about 3 seconds and then the normal power-on sequence will begin. When "ON" is selected, drive will start auto-
matically at power-up if it was running when powered down.
®
I/P 73
I/P 82
0.8 GPM
1.3 LPM
0.21 GPM
0.35 GPM
1.6 LPM
2.6 LPM
0.42 GPM
0.70 GPM
2.4 LPM
3.9 LPM
0.63 GPM
1.05 GPM
3.2 LPM
5.2 LPM
0.84 GPM
1.40 GPM
4.0 LPM
6.5 LPM
1.05 GPM
1.75 GPM
4.8 LPM
7.8 LPM
1.26 GPM
2.1 GPM
5.6 LPM
9.1 LPM
1.47 GPM
2.45 GPM
6.4 LPM
10 LPM
1.68 GPM
2.8 GPM
7.2 LPM
12 LPM
1.89 GPM
3.15 GPM
8 LPM
13 LPM
2.1 GPM
3.5 GPM
4
I/P 70
I/P 88
0.8 LPM
1.3 LPM
0.21 GPM
0.35 GPM
1.6 LPM
2.6 LPM
0.42 GPM
0.70 GPM
2.4 LPM
3.9 LPM
0.63 GPM
1.05 GPM
3.2 LPM
5.2 LPM
0.84 GPM
1.40 GPM
4.0 LPM
6.5 LPM
1.05 GPM
1.75 GPM
4.8 LPM
7.8 LPM
1.26 GPM
2.1 GPM
5.6 LPM
9.1 LPM
1.47 GPM
2.45 GPM
6.4 LPM
10 LPM
1.68 GPM
2.8 GPM
7.2 LPM
12 LPM
1.89 GPM
3.15 GPM
8 LPM
13 LPM
2.1 GPM
3.5 GPM
®
I/P 89
1.7 LPM
0.45 GPM
3.4 LPM
0.90 GPM
5.1 LPM
1.35 GPM
6.8 LPM
1.80 GPM
8.5 LPM
2.25 GPM
10 LPM
2.70 GPM
12 LPM
3.15 GPM
14 LPM
3.60 GPM
15 LPM
4.05 GPM
17 LPM
4.5 GPM