Sun threshold regulator (in connection with a suitable
sensor from the controller manufacturer)
You set the sun threshold value with this regulator (between about 2 kLux and
100 kLux).
The sun threshold value can be adjusted in 15 steps. When slowly turning the
regulator, the tubular drive clicks to indicate the setting changes.
- Left stop
+ Right stop
Changes made to the threshold value are transferred immediately.
When setting the threshold, ensure that no button is
pressed. If the set sun threshold value is exceeded, the sun
protection system extends after a delay of up to 5 minutes.
The sun protection system automatically retracts after the
sunshine level has been continuously below the threshold
value for about 15 minutes.

TEST mode

The TEST mode is activated by adjusting the threshold value. It automatically
ends after about 15 minutes. In TEST mode, the time for which the wind is
monitored is shortened.
Sun threshold value
Wind threshold value
Stage 1, retract at low sunshine level
Stage 15, retract at full sunshine

Factory default settings

Medium setting (about 25 kLux)
Left stop (about 2 m/s)