Herunterladen Diese Seite drucken

Digital Power Display - Elinchrom BRX 250 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für BRX 250:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Digital multi-display
The flash / modelling lamp power is displayed in f-stop compatible formats from 2.3 – 6.3 for
BRX 500. The flash power difference from (e.g.) 5.3 – 6.3 is 1f-stop.
The power range is 5 f-stops variable in 1/10th intervals which can be customised to (e.g.) 5/10th
etc.. During charging or discharging, the display «flashes». In case of overheating or malfunction,
the display shows «ER» for error.
Display
Joules / Ws
Note: The «BRX 250 - BRX 500» units have an integrated discharge system, protected by a thermal
switch. To avoid overheating, lower power settings of more than 2 f-stops by discharging manually
with the «Test» touch button.
Sychronisation socket
Standard socket with 3.5 mm mini-jack (5).
N.B. Do not link ELINCHROM units by cable to other manufacturers sync. outlets.
ELINCHROM uses the low voltage (5 V) for security reasons.
Open flash «test»
Having pressed the touch pad to release a flash, the green «READY»
light will appear again once the unit is recharged. If the green light does
not appear the charge system could be defective.
Please contact and send to an authorized Elinchrom service centre.
Eye-Cell – advanced photocell sensor
The standard photocell can be remotely triggered by another flash unit!
The BRX photocell is specially designed to work in studio light conditions
Direct light or other strong light sources may reduce the sensitivity of the cell.
10
2.3
3.3
31
62.5
4.3
5.3
125
250
6.3
500
Test and Ready (4)
English
5
Sync

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

Brx 500