Stop space is adjusted after reaching the opening and closing limit switch. This
blc
value is expressed in centimetres.
See section "How to adjust speed and braking".
It is activated with AUX 1 parameter only, preset to value 2.
TLS
The activation time of the service light is adjusted.
Ramp during acceleration. Value expressed in tenths of seconds.
TACC
See section "How to adjust speed and braking".
Ramp during deceleration. Value expressed in tenths of seconds.
TDEC
See section "How to adjust speed and braking".
It selects the operating mode of the AUX output:
1: Second radio channel. The output is controlled by the radio channel of the built-
in receiver (see RADIO Menu).
2: Service light. The contact closes for the time preset with TLS parameter. The
AUX
countdown starts at the inception of the opening operation.
3: Area light. The contact closes in the opening phase and remains closed for the
entire TCA time. It opens only with closed door.
See wiring shown in figure 5.
mENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands have
IBL
no effect during the opening phase.
Off: multi-flat function disabled.
During the TCA phase, the PP controls are enabled or disabled.
IBCA
On: PP controls are disabled.
Off: PP controls are enabled.
The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes the
automatic closure after 3 s.
SCL
If the photocell is activated during the opening phase, the operation is completed
and closure starts after 3s
Off: disabled rapid closure.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the
PRE
starting of the motor.
Off: disabled forewarning flashing light.
The Service Man function is enabled or disabled.
(The OPCL logics is automatically enabled).
On: Service Man operation. The Step-by-Step input becomes OPEN input, the
HTR
PED input becomes CLOSE input. The OPEN/CLOSE push buttons should be kept
pressed for the entire operating time.
Off: Automatic operation.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Enables blinker.
Off: Disables blinker.
The Encoder is enabled or disabled.
On: Activated Encoder.
ENC
Off: Not activated Encoder. The encoder only detects the door/gate stroke. In the
event of maintenance operations, it is advisable to deactivate it only temporarily.
The PHOT 1 input is enabled or disabled in the opening phase.
Pho1
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
Pho2
As per PH01, but referred to PHOT 2 input.
Pho3
As per PH01, but referred to PHOT 3 input.
16
LOGIC (LOG)
FUNCTION
1-20-(3)
1-240-(60s)
1-60-(20)
1-60-(20)
1-3-(1)
mEmO
ON-OFF-(Default)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)