Connect the Ethernet Cable

1. Connect the Ethernet cable's M12 connector to the vision system's ENET
connector.
2. Connect the Ethernet cable's RJ-45 connector to a switch/router or PC, as
applicable.
Connect the Breakout Cable
Note: Unused bare wires can be clipped short or tied back using a tie made of
non-conductive material. Keep all bare wires separated from the +24VDC
wire.
1. Verify that the 24VDC power supply being used is unplugged and not
receiving power.
2. Optionally, connect the I/O or serial wires to an appropriate device (for
example, a PLC, an encoder, or a serial device).
Note: When using an In-Sight 5604 line scan vision system, the RS-
232RX wire is used as Encoder A and the RS-232TX wire is used as
Encoder B.
3. Attach the I/O Breakout cable's +24VDC (White/Green wire) and 24V
COMMON (Brown wire) to the corresponding terminals on the power
supply.
CAUTION:
observe the polarity shown.
Never connect voltages other than 24VDC. Always