Precautions
Observe these precautions when installing the Cognex product, to reduce the risk of
injury or equipment damage:
In-Sight 5000 series vision systems are intended to be supplied by a UL or
l
NRTL listed power supply with a 24VDC output rated for at least 600 mA
continuous and a maximum short circuit current rating of less than 8A and a
maximum power rating of less than 100VA and marked Class 2 or Limited
Power Source (LPS). Any other voltage creates a risk of fire or shock and
can damage the components. Applicable national and local wiring
standards and rules must be followed.
Do not install In-Sight vision systems where they are directly exposed to
l
environmental hazards such as excessive heat, dust, moisture, humidity,
impact, vibration, corrosive substances, flammable substances, or static
electricity.
To reduce the risk of damage or malfunction due to over-voltage, line noise,
l
electrostatic discharge (ESD), power surges, or other irregularities in the
power supply, route all cables and wires away from high-voltage power
sources.
The housing of the vision system is internally connected to the system
l
ground wire (pin 8 of the Breakout cable). Therefore, if the mounting
surface of the vision system is at a non-zero ground potential, it is strongly
recommended that the vision system be mounted on an isolated or non-
conductive mount.