10 Re-pressing

Re-pressing is always necessary if a pressing operation has not been fully completed. Check the
system supplier's instructions to ascertain whether re-pressing is permitted. If it is permitted, please
note the following differences from the initial pressing operation that must be complied with.
WARNING!
Risk of injury from breaking claws on the adaptor jaw and damaged pins
on the press collar
Holding the press device incorrectly and changing its position before and during re-
pressing means that the claws can no longer grip the pins properly.
The tips of the claws may press directly on the pins, causing the claws and pins to
break and fragments to fly off.
Therefore:
Pos : 58 /RVT/R einigung, Wartung, R eparatur /01a - Vorsic ht - Einsc halter- ACO102, ACO152, AC O202XL, ACO401, AXI/AAP102 @ 0\mod_1390815867244_18.doc x @ 1770 @ 1 @ 1

11 Cleaning, maintenance and repair

CAUTION!
Risk of injury during cleaning or repair work from inadvertently pressing
the On switch.
Therefore:
Pos : 59 /RVT/R einigung, Wartung, R eparatur /02 - Ser vic eans chrift - AC O102, AC O152, ACO/EC O202, ACO202XL, EC O301, AC O401, AFP/EF P202, AXI/AAP102 @ 0\mod_1391000010165_18.doc x @ 1790 @ @ 1

Service addresses

Novopress GmbH & Co. KG
Scharnhorststr. 1
41460 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting Novopress or at
www.novopress.de.
Pos : 60 /RVT/R einigung, Wartung, R eparatur /03k - Infor mation Wartung - ACO403 @ 4\mod_1513691494013_18.doc x @ 33536 @ @ 1

Service intervals

Service and repair work may only be carried out by Novopress or the authorised Novopress specialist
workshops.
Information!
The next service is stated on the press device and the press collar.
This service must be performed at least once a year. If more than 2500 pressing
operations are carried out in a year, a service must be performed after these 2500
operations, at the latest.
An LED indicates that the service interval is expiring 100 pressing operations in
advance (see Section 8.1 Meaning of the LED display). )
Pos : 61 /RVT/R einigung, Wartung, R eparatur /04 - R egel mäßig - AC O401 @ 0\mod_1392970290536_18.doc x @ 1840 @ @ 1
Regularly (before use, at the start of the working day) and when soiled (Fig. 13)
Check the press collar, adaptor jaw and device for visible defects such as damage, material
cracks and other signs of wear. If defects are found, do not use the device any more. Replace
it or send it to an authorised specialist workshop.
Clean the press collar with compressed air.
Lubricate the adaptor jaw pins.
Spray the entire adaptor jaw with lubricant.
Remove deposits from pressing contour (K).
After positioning on the press collar, press the jaw levers on the adaptor jaw
together as far as possible using the grip. (Fig. 12)
Make sure that the claws of the adaptor jaw always grip the press collar pins
throughout the re-pressing operation. (Fig. 11)
Comply with the safety instructions and always remove the battery before
performing cleaning, servicing or repair work.