WARNING!
Risk of injury from ejected fragments
Material fatigue may cause the press tool to break.
Press tools are wearing parts.
Frequent pressing will result in material fatigue. Press tools worn or damaged in any
other way as the result of material fatigue can break even if used correctly; there is then
a risk of injury from ejected fragments. The risk of breakage is further increased in the
event of improper use.
Therefore
CAUTION!
Danger of crushing!
There is a risk of fingers and hands becoming crushed.
Therefore
CAUTION!
Keep fingers away from the at-risk zone when the adaptor jaw is closed.
(Fig. 4a)
Fingers may get crushed.
Therefore
Pos : 51 /RVT/Inbetri ebnahme und Betrieb/Ausg angsl age Press- Sc hlinge/02- Info-Gl eits egmente - AC O401 @ 3\mod_1490788774826_18.doc x @ 28848 @ @ 1
Information!
To ensure that the press collars function correctly, the sliding segments must be free to
move.
The sliding segments are always pressed back automatically into the correct starting
position by springs.
Therefore:
Pos : 52 /RVT/Inbetri ebnahme und Betrieb/Ver press en/05e - Punkt 1 - 6 ACO401 @ 3\mod_1490792088896_18.doc x @ 28948 @ @ 1
1.
Check that the nominal size of the press fitting matches the nominal size of the press collar.
Information!
Comply with the system supplier's instructions when positioning the press collar on the
press fitting.
CAUTION!
There is a risk that the press collar will break if it is positioned incorrectly
If the press collar is positioned incorrectly on the fitting the press collar may become
damaged.
Therefore:
Check the press tools for cracks and other signs of wear before each use.
Discard all press tools with material cracks or other signs of wear immediately and
do not use them any longer.
Only use press tools that are in perfect technical condition.
Keep all body parts and foreign objects away from the jaw levers on the fixed
adaptor jaw when initiating the pressing operation.
Do not hold the jaw levers of the adaptor jaw with your hands during the pressing
operation. Use the grip (7). (Fig. 1)
Leave the adaptor jaw open. (Fig. 4b)
Ensure that marking lines (M) on shells (C) are aligned with the edges of the sliding
segments (D) when the press collar is in starting position. (Fig. 5)
If this is not the case, have the press collars repaired.
The line (A) must be at the same height of the edge (B).
If this is not the case, remove the press collar again and reposition it
23
ACO403
(Fig. 7)
EN