Herunterladen Inhalt Inhalt Diese Seite drucken

Proceed As Follows - Rehau AWADUKT FLEX-CONNECT Montageanleitung

Rohrkupplung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Maintain a clean environment! No dirt must enter the tightening jacks�

Proceed as follows:

The insertion depth can be seen on the label or it can be determined by measuring the distance to the lip
protruding in the centre.
The insertion depth has to be marked on both pipes.
Following this, coat the spigot end up to the marking with a thin layer of lubricant.
Important:
Adapt the pipe coupler approximately to the larger pipe diameter by alternately tightening the two
tightening bands.
As soon as the sleeve
Push the pipe coupler up to the marking onto the larger pipe. Ensure that the tightening jacks are easily
accessible when pushing them on
Tighten the tightening jack on the larger pipe slightly that the pipe coupler still can be moved slightly on the
pipe.
Following this, insert the smaller pipe up to the mark.
Tighten the tightening jack on the smaller pipe using 15 Nm.
Tighten the tightening jack on the bigger pipe using 15 Nm.
Finished.
12
makes contact with the
pipe, it is mandatory
to use a torque
wrench.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Rehau AWADUKT FLEX-CONNECT

Inhaltsverzeichnis