Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Safety against backflow.
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
– check valve hasn't moved back
– Shower filter seal dirty
– Cartridge defective, calcified
– Cartridge defective
– Hot water limiter incorrectly set
– Flow limiter in handshower isn't
removed
– Filters are dirty
– check valve hasn't moved back
Assembly see page 31
Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Maintenance (see page 40)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions
(see page 36)
Flow diagram
(see page 37)
Operation
(see page 35)
Cleaning
see enclosed brochure
Spare parts
(see page 38)
Test certificate
(see page 40)
Remedy
– Exchange check valves
– Clean filter seal between shower
and hose
– Exchange cartridge
– Exchange cartridge
– Set hot water limiter
– Remove flow limiter
– Clean the filter / exchange filter
– Exchange check valves