TROUBLESHOOTING

Problem
The viewing image is not circular.
Image is blurred
"
" Is displayed during distance
- - -
measurement
Display flashes or no measurement
possible
"
" is displayed
Err
Cause
a. Your pupil is not in line with the exit
pupil of the eyepiece.
b. The eyecup setting not correct for
use with/without glasses.
Diopter setting incorrect
a. Minimum/maximum measuring
range exceeded
b. Insufficient object reflectivity
c. Insufficient ambient conditions
(visibility, etc.)
Battery exhausted
A memory card error has occurred
Remedy
a. Adjust eye-to-eyepiece alignment
b. Correct the setting: Eye glasses
users fold back the eyecup; the
eyecup remains folded out for users
without eye glasses.
Repeat diopter compensation procedure
Observe specified measuring range
limits
Replace the battery
Check if
– the memory card functions correctly
– the data stored on the memory card
is intact