Feature
The inverter switches off
when the consumer is
switched on.
11

Technical data

Rated input voltage:
Constant output power:
Peak output power:
Output frequency:
Idle current consumption:
Input voltage range:
Low voltage shutdown:
Maximum ambient temperature:
Fuse:
Dimensions:
Weight:
Testing/certification:
WAECO International complies with the industrial standard DIN ISO 9001.
Versions, technical modifications and delivery options reserved.
Possible cause
The starting current of the
consumer unit is too high.
12 V DC
100 W
200 W
50 Hz
0.25 A
10 V - 15 V
10 V
50 °C +/-5 °C
15 A
ø
66 mm x 173 mm
450 g
Technical data
Remedy
Compare the device power
with the maximum power of
the inverter.