Control panel

1.1 When plug in, follow the start music, unit is in standby status.
Display shows the temperature (5 ~ 35°C).
If ambient temperature is above 35℃,screen will show "H".
If it is below 5 ℃, it will indicate "L" and the unit will enter in
standby status.
1.2 ON/OFF POWER button: When press this button, model will enter cooling mode
(Setting temperature 22°C high speed fan. Press again, unit will shut off and play shut- off music.
1.3 Mode button MODE:
Press this key to choose Cooling, Heating (only for cool & heat model) Fan, or Dehumidifying Mode.
Press the "Mode" button until the "Auto" icon (see Figure 4) is lit.
Press "Temp +" or "Temp -" to set the desired room temperature. (16 ° C - 31 ° C)
1.4 Fan button FAN:
a) Under cooling mode:
LOW FAN(F1)→MIDDLE FAN(F2)→HIGH FAN(F3)→LOW FAN (F1)→...,goes like this.
b) Under fan model: same as cooling mode
c) Under dehumidifying mode, fan is working in low speed
d) If switch between cooling and fan, fan speed won't change.
1.5 Timer button TIMER:
Press it, TIMER icon will flash, "0" areas indicates 24:00; you can set your time through UP and DOWN
buttons. The HOUR number will change from 1,2,3...24; the Minute number will change from 10,
20,30...50.Auto-shut-off timer is only available when the unit on; auto-run timer is only available when the
unit is off. After timer setting accomplishes effectively, TIMER icon will keep on flashing until setting time is
due. If set again, history record will be cleared.
1.6 Up and Down button:can set temperature and timer.
Under cooling or heating mode, the sting temperature ranges from 16~30℃. If press Up and Down button
simultaneously, the unit will shift between ℃ to ℉.

Remote Control

1.Power:Press this key to turn on/off the button.
2.Mode:Press this key to choose cooling, heating, dehumidifying, fan
3.Up:Press this key to turn up temperature or adjust time.
4.Down:Press this key to turn down temperature or adjust time.
5.Fan:Press this key to set low/middle/high fan speed.
6.Auto Swing:Press this key to control swing function.
7. °C
°F:Press this key to choose Centigrade or Fahrenheit.
8.Timer:Press this key to set time. Within 5 hours, time interval
is half hour;from 5 hours to 24 hours, time interval is 1 hour. Once
set number will flash 5 times as confirmation .
9. Auto Clean: Press this button only when the machine is on,
then turn off the machine, the compressor will stop working, the motor will
keep working for some time to dry the evaporator.
Multi protective function
3.1 Water-full protection:
When the water level in the bottom water plate is surpassing warning level, the unit will alert automatically and
"FL" will flashes on LCD. Please discharge water in the machine according to Chapter "Water Drainage"
3.2 Anti-freezing protecting control(only for cool & heat model):
Under anti-freezing function, the "heat" will flash
3.3 Anti-heating protecting
Under heating mode, the compressor and motor will stop work until the temperature of the machine automatically
recover to ordinary heating status.
3.4 Compressor delay-protection
Except for the first power-on, the compressor can start at once. In other cases, the compressor runs under 3
minutes delay protection.
Timer
Display
Up
LED
down
Cool
Timer
Auto
Auto
Clean
Swing
MODE
FAN
TIMER
Mode
Fan speed
Heat
Fan
Dry
Cool
Fan
Dry
Timer
Energy
Auto
Auto
Energy
Clean
Swing
Saver
Saver
POWER
MODE
POWER
Auto Swing
FAN
Auto Swing
Auto Clean
TIMER
Auto Clean
On/Off