General
UKV has several different areas of use.
UKV can be used with external control of the heating
system. The heat pump then charges UKV with floating
or fixed condensing. The external control function con-
trols the heat distribution from UKV to the consumer.
If the flow to the heating system can be throttled with
radiator thermostats for example, install a UKV as an
intermediate tank. This ensures a secure flow for the
heat pump.
UKV also allows a greater flow to the heating system
than across the heat pump.
In some installations, so-called heat spikes occur as a
result of movements during temperature changes. To
eliminate temporary temperature changes, and thereby
prevent heat spikes, install a UKV after the heating
installation.
UKV can also be used to increase the system volume
and prevent malfunctions.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance. Rights to make any design or technical modifications are reserved.
©NIBE 2012.
INSTALLATION INSTRUCTIONS
UKV 102
Assembly
UKV is equipped with two hinges. If you
want to change the side on which the
plunger pipe is located, the hinges can be
reversed. See Fig. 1 and Fig. 2.
Prior to commissioning, we recommend that you run
the heating circuit and any impurities that are
trapped in the filter clean, then the system is fully
operational