Herunterladen Inhalt Inhalt Diese Seite drucken

Installation, Relocation And Inspection; Specifications - Mitsubishi Electric MS-GD80VB Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für MS-GD80VB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13

INSTALLATION, RELOCATION AND INSPECTION

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the unit will be buried in snow.
• Inside the mobile vehicles such as a crane truck, ship, etc.
• Drain the water from the unit to the soil which has good drainage.
• Cooling and heating capacity may get lowered 10% in the places
where poor ventilation and short-cycle of air exchange is likely
to occur.
WARNING :
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will
be generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
WARNING :
The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc.
Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

SPECIFICATIONS

Set name
MS-GD80VB
Model
Indoor
MS-GD80VB
Outdoor
MU-GD80VB
Function
Power supply
Capacity
kW
Input
kW
Indoor
kg
Weight
Outdoor
kg
Refrigerant filling
kg
capacity (R410A)
Indoor
IP code
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Indoor
dB(A)
Noise level
(High/Med./Low)
Outdoor
dB(A)
12
The installation location of the outdoor unit should be at least
3 m away from the antennas for TV sets, radios, etc. In areas
where the reception is weak, provide greater space between
the outdoor unit and the antenna of the affected device if
operation of the air conditioner interferes with radio or TV
reception.
Inverter-type
To prevent the effects
fluorescent lamp
of a fluorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent the
picture
1 m
distortion or
100 mm or
or more
more
the noise.
1 m
TV
Cordless
or more
phone or
Portable
3 m
phone
Radio
or more
* The required space depends on the type of outdoor unit.
NOTE:
MSH-GD80VB
1. Rating condition
MSH-GD80VB
MUH-GD80VB
Cooling
Cooling
Heating
~ /N, 230V, 50Hz
8.0
8.0
9.4
3.32
3.32
3.58
16
2. Guaranteed operating range
75
77
2.40
2.40
IP20
IP24
1.64
4.15
47/42/37
47/42/37
55
55
CAUTION:
• Earth the unit.
Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places, etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
wall, etc.
Inspection and maintenance
Well-
ventilated
dry place
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
500 mm or
dust, etc. This may cause water leakage from the unit.
more
• It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.
Operating sound considerations
• Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.
• If an abnormal sound is heard during operation, consult your dealer.
• Choose a place which endures the unit weight enough and does not amplify the unit vibration.
• Choose a place in which the operation sound and air blow from the unit don't bother the house next door.
Relocation
• When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and
work are required.
WARNING :
Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
Cooling —
Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB, 24°C WB
Heating —
Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
Indoor
Outdoor
32°C DB
43°C DB
Upper limit
23°C WB
Cooling
21°C DB
21°C DB
Lower limit
15°C WB
27°C DB
24°C DB
Upper limit
18°C WB
Heating
20°C DB
-10°C DB
Lower limit
-11°C WB
If you have any questions, consult your dealer.