Trouble shooting

Problem
Appliance won't
start
Inferior cutting
performance
Saw runs with
difficulty, chain
(1
) comes off
Chain (
1)
becomes hot,
smoke devel-
opment during
sawing, discolor-
ation of the rail
Telescopic arm
cannot be locked
No charging
process possible
Possible cause
Battery (
11) discharged
Battery (
11) not inserted
Safety switch (
12) not
pressed properly
On/Off switch (
13) defective
Incorrectly mounted saw chain
1)
(
Saw chain (
1) blunt
Chain tension insufficient
Chain tension insufficient
Too little chain oil
17b) loose on
Allen screw (
the quick release (
Battery (
11) is too hot (red
flashing light on battery)
Battery (
11) not inserted
correctly in the battery charger
Power plug of the battery
charger (
22) not inserted
correctly
Battery contacts contaminated
Defective battery (

Fault correction

Recharge battery (see „Charging")
Insert battery (see „Operation")
Turn on (see "Operation")
Send in to Service Centre for repair
Mount saw chain correctly (see "As-
sembling instructions")
Sharpen cutting teeth or place on
new chain
Check chain tension
Check chain tension
Check oil level and, where appro-
priate, refill with chain oil,
check oil automatic system and,
where appropriate, clean oil outlet
channel (
by customer service
Check fine-tuning for lubrication
system (oil regulation button).
Tighten Allen screw
17)
Allow battery to cool down
Insert battery correctly (see "Charg-
ing process")
Insert power plug into the socket
correctly
Clean contacts
Replace battery (see "Spare parts/
11)
Accessories")
GB
IE
CY
27) or have repaired