Herunterladen Inhalt Inhalt Diese Seite drucken

GUTMANN Capa Montageanleitung Seite 23

Vorschau ausblenden Andere Handbücher für Capa:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
the relevant applicable installation regu-
lations and installation instructions pro-
vided by the manufacturer of the gas
appliance. The extractor hood may only
be installed at a minimum height of 650
mm above gas cookers if the following
nominal heat loads (Hs) are not ex-
ceeded:
Gas stoves
Load from one gas ring max. 3.0 KW
Load from all gas rings max. 8.3 KW
Load from oven
Gas hobs
Load from one gas ring
Load from all gas rings
We reserve the right to make technical
changes.
Installation instructions
for recirculation C-
Version
General:
Before the extractor hood leaves the
works it undergoes an extensive func-
tional test.
To provide a better technical under-
standing of the interrelationship of func-
tional components, the extractor hood is
delivered pre-assembled in its final con-
dition. However, it must be partially dis-
mantled prior to installation according to
the following instructions.
A = Mounting frame
B = Hood upper section
C = Installation holes
D = Hood lower section
E = Securing bolts
max. 3.9 KW
max. 3.9 KW
max.11.3 KW
1. The extractor hood must be carefully
removed from the packaging by 2 peo-
ple and placed on the mounting lift.
Then prepare the installation location on
the ceiling. To achieve optimum extrac-
tion capacity, the hood must be posi-
tioned in the middle above the cooking
hob. Use a plumb line to mark the cen-
tre of the hood on the ceiling.
2. Take the installation frame (A) to
transfer the fastening holes for the ex-
tractor hood (2 and C) and for the
mounting frame (1 and A) onto the ceil-
ing.
en
23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis