Herunterladen Inhalt Inhalt Diese Seite drucken

GUTMANN Sombra Montageanleitung Seite 12

Deckengerät
Vorschau ausblenden Andere Handbücher für Sombra:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
Important Information
General
These Installation instructions contain
important Information which must be
observed in order that the extractor
hood can be installed and operated
without risk or difficulties. Keep these
Installation instructions in a safe place
for subsequent use. Follow the instruc-
tions of the cooking appliance manufac-
turer for Installation of extractor hoods.
The assistance of another person will
facilitate Installation. Replace defective
parts with original spare parts or with
parts named by the manufacturer.
Note: If extractor hoods feature external
fan motors, the Installation of the fan
motor can be found in separate installa-
tion instructions.
Safet instructions
Dinger
Installation, connection, startup and
repairs may be carried out by techni-
cians only. Technicians can specify a
suitable attachment and exhaust air
conduction for the extractor hood. The
attachment must be suitable for the
weight of the extractor hood and for the
load on the wall. Observe the pullout
values of the supplied wall plugs. These
have the following values depending on
the wall:
10 mm wall plugs:
Concrete B25
Brick MZ20
Solid calcium silicate brick KSV204.8 kN
If the wall is made of other uncertain
materials, consult a building specialist,
e.g. a structural engineer or an architect
to ensure t hat the extractor hood can
be installed securely.
Risk of injury
The hood structure may have sharp
edges caused by the manufacturing
process. Wear protective gloves during
installation.
12
Risk of electric shock
The mains voltage must correspond
with the specifications on the rating
plate. The rating plate is situated near
the filters inside the hood. Connect the
extractor hood to a correctly installed
earthed socket only. The socket must
be easily accessible following installa-
tion so that the extractor hood can be
isolated if required. If the extractor hood
is to be permanently connected (e.g. if
there is no appropriate socket), it may
be connected to the mains by an electri-
cian only. If the extractor hood is to be
permanently connected, it must be con-
nected to a single electric circuit with
disconnector. Switches with a contact
opening of at least 3 mm and all-pole
switches, e.g. LS switches and contac-
tors, are regarded as disconnectors.
Before connecting the extractor hood to
the power supply, disconnect the mains
circuit(s). Before drilling fixing holes,
ensure that there are no electric cables
which could be damaged by the drilling.
When preparing the power supply con-
nection, ensure that the extractor hood
can be connected without difficulty.
Observe local regulations.
Exhaustair conduction for exhaustairmode
The exhaust air must not be conducted
into a chimney which is used to remove
exhaust gases from appliances which
use fuel (e.g. gas). Observe the official
regulations for the removal of exhaust
air. When preparing the exhaust air
9.4 kN
route, ensure that the extractor hood
5,2 kN
can be connected without difficulty. The
exhaust air hose must not be kinked.
Solid fuel fireplaces
The extractor hood must not be installed
above a solid fuel fireplace which is a
fire hazard (e.g. flying sparks) unless
the fire-place has a sealed, non-
removable cover.
Minimum distance from an electric
cooking appliance.
Minimum distance between the lower
edge of the extractor hood and hot-
plates/ hobs is min. 650 mm.