3. Settings and enquiries
Operating the menu button causes the respective sub-menus with the current display or the setting parameter, to appear one after
another. The selected sub-menu is indicated by the menu symbol.
Return to the standard display and the storage of changed setpoint parameters is effected automatically.
Enquiry to determine outlet temperature
LCD display
Button Note
°
Enquiry to determine energy consumption of water heating
LCD display
Button Note
kWh
Limescale display On/Off
LCD display
Button Note
Ca
Ca
If the electronics identify an appropriately high level of limescale on
the heating element, it is recommended that descaling is carried out.
If the limescale display is „On", the „Ca" symbol (limescale) will
under these circumstances appear in the standard display.
If the limescale display is „Off", an enquiry can be made using menu
selection.
20
Menu selection
Display of current outlet
temperature
Menu selection
Display of accrued energy
consumption for water heating
(approximate value)
Alternatively hold down 'Rückstel-
lung' (Reset) button for longer
than 3 seconds
Menu selection
: limescale display „On"
(condition as supplied)
: limescale display „Off"
Changeover „On/Off"
Display of current „limescale
value"
: descaling of heating element
recommended
: no recommendation
Temperature limitation On/Off
LCD display
Button Note
ECO
°
If the temperature limitation is „On", the preset value will
automatically be adopted as a maximum value for the setpoint
temperature setting.
Menu limitation On/Off
LCD display
Button Note
°
When menu limitation is „On", a fixed changeover to the setpoint
temperature menu is effected.
Only the rapid heating and temperature setting functions remain
adjustable.
Menu selection
: temperature limitation „Off"
(condition as supplied)
: temperature limitation „On"
Changeover „On" / „Off"
Range of adjustment 40 - 65 °C
- symbol in the standard
ECO
display when temperature
limitation is „On"
On:
Keep pressing down for at least
3 seconds until the setpoint
temperature menu flashes once.
Setpoint temperature menu is
continuously displayed (standard
display - menu limitation).
Setting of setpoint temperature
Rapid heating
No menu selection possible
Preset values continue to be
maintained.
Heating-up, limescale and service /
fault indication appears
automatically.
Off:
Keep pressing down for at least
Keep pressing down for at least
Keep pressing down for at least
Keep pressing down for at least
Keep pressing down for at least
3 seconds until the mixed water
3 seconds until the mixed water
3 seconds until the mixed water
3 seconds until the mixed water
3 seconds until the mixed water
display flashes once.
display flashes once.
display flashes once.
display flashes once.
display flashes once.
Mixed water quantity is continu-
ously displayed (standard display).
Free menu choice possible
(condition as supplied).