Guide for customer
The installation must be done by
professional referring to the Instal-
lation instructions.
The wiring must be done by quali-
fied electrician according to the
electrical safety requirements.
The customer should have a quali-
fied power supply which coincides
with the tag of air conditioner, the
normal voltage should be in the
range of 90-110% of its rated vol-
tage.
The air conditioner must be well
grounded, the switch of the main
power of airconditioner must be
reliably grounded.
If your air conditioner is not fitted
with a supply cord and a plug, an
all-pole switch must be installed
in the fixed wiring and the distan-
ce between contacts should be no
less than 3.0 mm.
If your air conditioner is permanen-
tly connected to the fixed wiring
and have a leakage current that
may exceed 10 mA, leakage pro-
tector must be installed in the
fixed wiring, operating current of
which shall not exceed 30 mA.
The power supply circuit should
have leakage protector and air
switch of which the capacity sho-
uld be more than 1.5 times of the
maximum current.
NOTICES
The air conditioner must be instal-
led on well strong supporter.
The appliance shall be installed
in accordance with national wiring
regulations.
Fix the machine firmly, otherwise
it will produce abnormal noise and
vibration.