Guide for customer
•
The installation must be done by
professional referring to the Instal-
lation instructions.
•
The wiring must be done by quali-
fied electrician according to the
electrical safety requirements.
•
The customer should have a quali-
fied power supply which coincides
with the tag of air conditioner, the
normal voltage should be in the
range of 90-110% of its rated vol-
tage.
•
The air conditioner must be well
grounded, the switch of the main
power of airconditioner must be
reliably grounded.
•
If your air conditioner is not fitted
with a supply cord and a plug, an
all-pole switch must be installed
in the fixed wiring and the distan-
ce between contacts should be no
less than 3.0 mm.
•
If your air conditioner is permanen-
tly connected to the fixed wiring
and have a leakage current that
may exceed 10 mA, leakage pro-
tector must be installed in the
fixed wiring, operating current of
which shall not exceed 30 mA.
•
The power supply circuit should
have leakage protector and air
switch of which the capacity sho-
uld be more than 1.5 times of the
maximum current.
NOTICES
•
The air conditioner must be instal-
led on well strong supporter.
•
The appliance shall be installed
in accordance with national wiring
regulations.
•
Fix the machine firmly, otherwise
it will produce abnormal noise and
vibration.