Herunterladen Diese Seite drucken

Conrad 39 61 98 Bedienungsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• After you have made the last setting (date) and pressed the "CLOCK" button again, the setting mode is
exited.
The setting mode is also exited and the previous settings saved when you do not press any button for a
few seconds.
Switching between display (of time, date, day of the week)
• Repeatedly press the "CLOCK" button to switch between the display of time, date and day of the week.
Display of the date and day of the week will return automatically to time after a few seconds.
Switching between temperature displays (room / ambient temperature)
Repeatedly press and release the "LIGHT/CHANNEL" button on the top of the weather station to switch
between the room and ambient temperature displays (room temperature = "IN" symbol to the left of the
temperature display).
If more than one outdoor sensor is registered to the weather station, the display of the corre-
sponding outdoor sensor can also be selected ("Ch1", "Ch2" and "Ch3").
If the "
" symbol appears above the temperature display, then the display switches automatically between
room and ambient temperatures.
Switching between temperature units °C/°F
Briefl y press the "°C/°F" button to switch between °C (degrees Celsius) and °F (degrees Fahrenheit).
In the outdoor sensor, this button is found in the battery compartment; remove the battery compartment
cover to turn it on.
Alarm function
a) View alarm or turn alarm function on/off.
• Press the "ALARM" button briefl y to display the alarm time on the display. Top right shows "AL."
• If you again (repeatedly, if necessary) briefl y press the "ALARM" button you can turn the alarm on or off.
With activated alarm function, a small bell icon appears on the right top of the display.
b) Setting the alarm
• Press and hold the "ALARM" button, until the hours for the alarm time fl ash.
• Set the hours for the alarm time using the "+" button (hold down the button longer for quick adjustment).
• Briefl y press the "ALARM" button, the minutes of the alarm time fl ash.
• Set the hours for the alarm time using the "+" button (hold down the button longer for quick adjustment).
• Briefl y press the "ALARM" button again (or wait a few seconds, without pressing any button), the setting
mode is exited.
c) Stopping the alarm signal
When the alarm signal is sent, press the "ALARM" button to stop it.
Perform sensor search for outdoor sensor(s)
Press and hold the "LIGHT/CHANNEL" button until a beep is heard and the channel indicator fl ashes on the
bottom of the display of the weather station. The weather station will now perform a search for the signal of
the available outdoor sensors, this may take several minutes.
Perform sensor search for the rain sensor
Press and hold the "SEARCH" button until a beep is heard and the rainfall display fl ashes on the display of
the weather station. The weather station will now perform a search for the signal of the rain sensor, this may
take several minutes.
Switching between displays of the rainfall recorded
Press the "MODE" button to toggle between the following:
"DAILY"
Daily rainfall
"WEEKLY"
Weekly rainfall
"MONTHLY" Monthly rainfall
"TOTAL"
Total rainfall
Resetting display of the rainfall recorded
• Select at fi rst the appropriate display which you want to reset ("DAILY", "WEEKLY", "MONTHLY" or
"TOTAL") as described in "Switching between the displays of rainfall".
• Hold down the "MODE" button for about 3 seconds until a beep can be heard. The corresponding display
is now reset to "0.0".
Selecting the display unit of rainfall
Briefl y press the "UNIT" button to toggle between the display unit "mm" and "in" (= inch).
Graphic display for temperature / rainfall
• The bar graph on the left of the display is used to display the temperature. When the temperature rises,
even more bars of the bar graph are displayed.
• The rainfall display on the right of the display shows the actual rainfall graphically as a function of the
number of raindrops.
Display Light
• Press the "ON/OFF" button to switch the lighting on or off.
Note that the display light is turned off automatically after some time on battery power; this is to
save power.
Permanent display lighting is possible only when you connect the supplied wall plug transformer,
but not during battery operation.
• When using batteries, the lighting is activated for a few seconds by briefl y pressing the "LIGHT/CHANNEL"
button. After that the lighting will turn off automatically.
Maintenance and Cleaning
The product is maintenance-free.
Use a clean, soft, dry cloth for cleaning the weather station and the outdoor sensor. Do not apply too much
pressure on the casing or the glass; this can cause scratch marks.
Do not use any chemical cleaning agents, as they can discolour the plastic casing.
Check the rain sensor time and again whether the rain collection opening is covered by, e.g. leaves.
Disposal
a) Product
Dispose of an unserviceable product in accordance with the relevant statutory regulations.
b) Normal and Rechargeable Batteries
As end user, you are required by law (Battery Regulation) to return used batteries and rechargeable batte-
ries. Do not dispose of used batteries in the household waste!
Contaminated normal / rechargeable batteries are labelled with the following symbols to indicate
that disposal in the domestic waste is forbidden. The symbols of the relevant heavy metals are:
Cd=Cadmium, Hg=Mercury, Pb=Lead (marked on batteries/rechargeable batteries, e.g. under
the rubbish bin symbol shown to the left).
You can return your used normal/rechargeable batteries free of charge at the offi cial collection points of your
community, in our stores, or at places where batteries or rechargeable batteries are sold!
You thereby fulfi l your statutory obligations and contribute to the protection of the environment.
Declaration of Conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this product
conforms to the fundamental requirements and the other relevant regulations of the directive 1999/5/EC.
The Declaration of Conformity for this product can be found at www.conrad.com.
Technical Data
a) Weather station
Power supply ........................................6 V/DC via external power supply or 3 batteries of type AAA/Micro
Temperature measurement range ........0 °C to +50 °C (+32 °F to +122 °F)
Accuracy ...............................................+/-1.5%
Number of outdoor sensors ..................max. 3
Dimensions ...........................................52 x 171 x 40 mm (W x H x D)
Weight ..................................................120 g (without batteries)
b) Outdoor sensor
Power supply ........................................2 batteries of type AAA/Micro
Temperature measurement range ........-20 °C to +60 °C (-4 °F to +140 °F)
Accuracy ...............................................+/-1.5 °C
Transmission frequency........................433 MHz
Transmission channels .........................3 (switchable)
Range ...................................................max. up to 30 m (with direct view of the weather station)
Transmission interval ............................2.5 minutes
Dimensions ...........................................65 x 89 x 31 mm (W x H x D)
Weight ..................................................70 g (without batteries)
c) Rain sensor
Power supply ........................................2 batteries of the type AA/Mignon
Rainfall measurement range ................0 - 9999 mm (0 - 393.66 Zoll (inches))
Transmission frequency........................433 MHz
Range ...................................................max. up to 30 m (with direct view of the weather station)
Dimensions ...........................................59 x 85 x 149 mm (W x H x D)
Weight ..................................................110 g (without batteries)
Weight ..................................................120 g (without batteries)
d) Wall plug transformer
Operating voltage .................................230 V/AC, 50 Hz
Output ...................................................6 V/DC, 300 mA
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2013 by Conrad Electronic SE.

Werbung

loading