Discharging end voltage per cell
DSCH VOLTAGE
3.0V/CELL
Here, the voltage per cell at which discharging ends can be set.
Attention!
Never set the voltage too low. For lithium rechargeable batteries, this may cause deep discharge and
permanent damage to the rechargeable battery!
Observe the table in chapter 7 and any special information of the rechargeable battery manufacturer.
Charging end voltage per cell
TVC=YOUR RISK!
Here, the voltage per cell at which discharging ends in lithium rechargeable batteries can be set.
Attention!
Never set the voltage too high. This can result in a fire or explosion with Lithium batteries!
Observe the table in chapter 7 and any special information of the rechargeable battery manufacturer.
Deactivation at overtemperature
TEMPERATURE
CUT-OFF
The charger can automatically cancel charging/discharging if the rechargeable battery exceeds the temperature set
here.
To use this function, an external temperature sensor is required (not enclosed). It must be connected to the
respective socket of the respective charger channel.
If this function is to be used on each channel, you need a total of 4 separate temperature sensors.
Maintenance charging current (for NiMH and NiCd only)
TRICKLE
Set the maintenance charging current here. When a NiMH or NiCd rechargeable battery is fully charged, it will lose
part of its capacity again by self-discharge. The maintenance charging current (short charging impulses, no conti-
nuous charging current!) ensures that the rechargeable battery remains fully charged. Thus also prevents crystal
formation in the rechargeable battery.
4.20V
50C
100mA