Controls
Illustration (refer to fold-out page)
1. 3 1/2 digit LED (light emitting diode) display
2. 2-pole connector(s) with the following pin assignment (rear view
from above looking downwards)
High-input = „+" measuring input
Low-input = „-" measuring input (earth)
3. Three 2-pole connector(s) with the following pin assignment
(Rear view from above looking downwards)
„+" Power supply input, 5 V.d.c. (stabilised) from SELV supply
(N.C. = not connected)
„-" Power supply input = earth not signal earth
4. Soldering lugs on the board, bottom left (DP3) and right (DP2
and DP1) for determining the decimal points, DP1 = 0.000, DP2
= 00.00, DP3 = 000.0.
Contents
Introduction ......................................................................................4
Proper Use........................................................................................5
Controls (fold-out page) ................................................................3/6
Contents ...........................................................................................6
Safety Instructions............................................................................7
Performance of Measurements, Commissioning .............................9
Disposal ..........................................................................................10
Troubleshooting ..............................................................................11
Care and Maintenance ...................................................................12
Technical Data, Measuring Tolerances ...........................................12
6

Safety Instructions

• This measuring module may not be used in installations of over-
voltage category III according to IEC 664. The measuring module
is not protected against arc explosions (IEC 1010-2-031, clause
13.101).
• Keep measuring devices away from children!
• On commercial premises, the accident prevention regulations of
the Association of Industrial Professional Associations with res-
pect to electrical systems and operating equipment must be ob-
served.
• In schools, training establishments, hobby and self-help works-
hops, the use of measuring modules shall be responsibly super-
vised by trained personnel.
• Take particular care when dealing with voltages greater than 25
V.a.c. or 35 V.d.c. At these voltages, contact with a live conduc-
tor can cause an electric shock which is life-threatening. There-
fore, first disconnect from the voltage source, connect the mea-
Page
suring device to the terminal of the voltage source to be measu-
red, set the required voltage range on the measuring device and
then reconnect the voltage source. On completion of the measu-
rement, disconnect the voltage source and disconnect the mea-
suring cables from the terminal of the voltage source.
• Isolate the panelmeter from the measuring circuit before carrying
out any operations on the measuring unit.
• Check your panelmeter and its (connector) measuring cables for
damage before each measurement.