5. CommISSIoNING
Regularly check the technical safety of the device e.g. for damage to the housing or
the power cable.
Make sure the load is switched off when you connect it to the power supply unit.
Connecting the power cable
• Connect an IEC power cable (not included in the package) to the IEC connector (7) on the
power supply unit. Check the firm fitting of the plug in the unit.
You can order a suitable power cable e.g. using the item no. 510514.
• Connect the mains plug to a standard mains socket.
• Switch on the power supply unit using the operating switch (1). The power supply unit will
indicate the correct operation with a light indicator (3).
Connecting a consumer load
In selecting the connecting cables (cable) make sure that the cable cross-
section is adequate (on account of the current load/cable losses) and that the
insulation is intact.
• The output voltage is preset to approximately 13.8 V direct current (=DC). Prior to connect-
ing a consumer load, check the output voltage using a voltage meter and if required, adjust
the output voltage on the setting controller "V ADJUST" (4) using a suitable screw driver.
The rated voltage is up to 8 ampere, depending on the version of the device, and it is
limited by the power supply unit. A manual current limiting by the user is not possible.
The power supply unit can have a slightly higher load in order to bridge inrush current
peaks. Observe the information in the technical data.
• Make sure the consumer is switched off.
• Connect the positive terminal (+) of the load with the red connection socket "+" (5) and the
negative terminal of the load with the black connection socket "-" (5).
• The connection is made using standard 4 mm plugs. You can attach cable strands using
screw terminals. To this end, the socket heads can be screwed on.
• Switch the consumer load on. The power consumption of the connected consumer load is
shown on the current display (2).
make sure that the load is switched off when being connected to the power
supply unit. Sparks may be generated when a switched-on consumer is
connected to the jacks. This may damage the screw terminals as well as the
connected cables.
• To disconnect the consumer load from the power supply unit, proceed in reverse order.

6. TRoUBLESHooTING

By purchasing this power supply unit you have acquired a product with state of the art design
that is operationally reliable.
Nevertheless, problems or faults may occur.
Therefore, we would like to describe here how to eliminate possible faults:
Always follow the safety instructions!
Problem
Solution
The power/operation
No mains voltage?
indicator does not
• Check the circuit breaker for the mains socket
light up.
• Check the proper fit of the power cable in the power supply
unit and in the mains socket
• Check the device fuse at the back of the unit
• The power supply unit is overloaded and the output has been
switched off. Remove the consumer load(s) and check the

technical data.

Connected consumer
Is the power supply unit overloaded?
load doesn't work.
• Remove the consumer load(s) and check the technical data.
Has the polarity been reversed?
• Check the correct polarity of the consumer load.
Any other repair work must be carried out only by a qualified expert who is fa-
miliar with the hazards involved and with the relevant regulations. Unauthor-
ized modifications or repairs to the device invalidate the guarantee/warranty.

7. CLEANING AND mAINTENANCE

You do not need to service the power supply unit, apart from an occasional cleaning.
Always unplug the power plug from the mains socket before cleaning the device.
To clean the device, use a clean, slightly damp, fuzz-free, antistatic cleaning cloth.
Leave the device to dry completely before putting it into operation again.
Fuse replacement
If it is no longer possible to switch on the power supply unit, the device fuse is probably defec-
tive and has to be replaced.
Proceed as follows to replace the device fuse:
• Switch off the power supply unit and remove all the connection and mains cables.
• Release the bayonet lock on the fuse bracket (6) at the rear with slight pressure in the
direction of the arrow (a quarter turn). Pull the fuse insert out of the device.
• Replace the defective fuse with a new fine-wire fuse (5x20 mm) of the same type and rated
current. You can find the fuse data in the technical data.
• Insert the fuse bracket and lock it in the reverse order.
make sure that only fuses of the type stated and of the rated current specified
are used as a replacement. Using repaired fuses or bridging the fuse bracket
is not permitted.
If you have technical questions concerning the use of the device, feel free to
contact our technical support.
8. DISPoSAL
Electronic devices are recyclable material and do not belong in the household
waste.
Please dispose the device, when it is no longer in use, according to the current
statutory requirements.
You thus fulfil the legal requirements and make your contribution to protecting the
environment!
9. TECHNICAL DATA
Type
FPS-1132
Item No.
1195956
Operating voltage
Power input max.
110 VA
Output voltage DC
Rated output current DC
2 A
Peak output current DC
4 A
Effective residual ripple
Controller response to a
≤ 10 mV
load change 0~100%
Controller response to +/-
≤ 10 mV
10% mains voltage change
Stability of the output
20 mV/h
voltage
Socket diameter DC
4 mm
Device fuse
Slow blow-
ing fuse,
Fine-wire fuse 5 x 20 mm
250 V
T 0.5 A
Protection class
1
Operating temperature
Relative humidity
Dimensions (W x H x D)
164 x 90 x
in mm
230
Weight
2.1 kg
G
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.
FPS-1134
FPS-1136
FPS-1138
1196063
1196090
1196091
230 V AC (+/- 10%) / 50 Hz
160 VA
200 VA
290 VA
11 V (+/- 0.2 V) bis 14 V (+/- 0.5 V)
4 A
6 A
8 A
6 A
8 A
10 A
≤ 5 mV
≤ 10 mV
≤ 15 mV
≤ 20 mV
≤ 10 mV
≤ 10 mV
≤ 10 mV
20 mV/h
25 mV/h
25 mV/h
4 mm
4 mm
4 mm
Slow blow-
Slow blow-
Slow blow-
ing fuse,
ing fuse,
ing fuse,
250 V
250 V
250 V
T 0.63 A
T 1.0 A
T 1.25 A
1
1
1
+5 to +40 °C
max. 85%, non-condensing
164 x 90 x
164 x 113 x
164 x 113 x
230
240
206
2.9 kg
4.1 kg
5.1 kg