- GB -
Drinking water system in accordance with the regulations
− Drinking water systems must meet the national regulations, and installations may only be carried out by a trained
plumber.
− Trained plumbers are persons who, on the basis of their vocational education, training, knowledge and experience,
are capable of and authorised to judge and carry out the work with which they have been commissioned. This also
includes the recognition of possible hazards and the adherence to the pertinent regional and national standards,
rules and regulations.
− If you have any questions or problems, please consult a qualified plumber.
− The unit may only be connected if all prescribed measures for protecting the drinking water are adhered to.
− Drinking water may only be discharged into a non-drinking water system via a free flowing outlet (with air gap
separation).
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating instruc-
tions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
Mechanical installation
Installing the solenoid valve
Note!
− The installation of the solenoid valve described in the following may only be performed by a trained
plumber.
− Ensure that excess water (pond overflow water) can drain via a pond overflow or other suitable protective
measure into the sewer system.
How to proceed:
C
− The drinking water supply pipe to be used for replenishment must be thoroughly flushed out to ensure that the
function of the solenoid valve is not impaired by any residue.
− Remove the protective plugs from both ends of the solenoid valve.
− Connect the solenoid valve to the drinking water supply pipe. Ensure that the arrow on the bottom of the valve
points in the flow direction of the drinking water.
OASE recommends: Fit the solenoid valve with the solenoid pointing upward. This increases its operating life and
reduces calcium and dirt deposits.
− Fit the G 1/2" pipe to the outlet (OUT) of the solenoid valve.
− Complete the installation with a free flowing outlet (with air gap separation).
D
OASE recommends: Conduct the water flowing out of the free flowing outlet (3) (with air gap separation) through a
DN 50 pipe (9) or larger, or via a water course into the pond.