Installation and connection

B
• Install the transformer at least 2 m from the edge of the pond.
• Position the unit in such a way that it does not present a hazard to anyone.
• Ensure safe and stable seating. Ensure the sufficient load carrying capacity of the wall or ground for installation on
the wall or on the base.
• For installation above water: Ensure a safety distance of at least 50 cm from combustible material.
Do not cover the unit!
Wall or ground installation
C
• The base foot can either be placed on the ground or bolted to a firm base or load bearing wall.
Installation on the ground stake
7.
How to proceed:
0.
D
1. Pull the spotlight sideways from the base foot.
2. Push the spotlight sideways onto the ground stake and push the ground stake almost completely into the ground.
Check its stability.
Tilting the unit
E
• Turn the holding screw counterclockwise and tilt the unit as required. To fasten in place turn the holding screw
clockwise.
Connect the unit
F
• Connect the connection cable of the spotlight to the socket on the transformer and hand-tighten the union nut.
Start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

• Prior to reaching into the water, disconnect the power supply to all units used in the water.
• Disconnect the power plug prior to carrying out work on the unit.
Switching on: Insert the power plug of the transformer into the socket.
• Check the function of the spotlights.
Switching off: Disconnect the transformer power plug.

Remedy of faults

Malfunction
Lamp does not light up
Luminosity decreases
Water inside the spotlight housing
S
10
Cause
Power supply interrupted
Bulb defective
Lamp glass soiled
The brightness of the bulb reduces as the
operating time increases
Seal defective
Remedy
Check power supply
Replace bulb
Clean
Replace bulb
Check sealing rings and replace, if necessary