Assembly of the UVC clarifying unit (F)
− Insert the quartz glass including the O ring against the stop in the unit head (6).
− Press the O ring into the gap between unit head and quartz glass.
− Tighten the clamping screw clockwise up to the stop (7).
− Tighten the self-tapping screw (8).
− Check the O-Ring at the unit head for damage and replace, if necessary (9).
− Carefully push the unit head into the housing while applying slight pressure. Ensure that the tenons at the housing
engage in the grooves of the bayonet closure.
− Turn the unit head clockwise against the stop while applying slight pressure.
− Refit the cover for the UVC pre-clarifying unit.
Storage/Over-wintering
− Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to
be expected.
− Drain and thoroughly clean the unit, check for damage.
− Remove, clean, dry and store all filters in a frost-free environment.
− Ensure that the storage place is inaccessible to children.
− Cover the filter container such that the ingress of rain water is excluded.
− Drain all hoses, pipes and connections as far as possible.

Wear parts

The UVC lamp, the quartz glass and the filters are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.

Remedy of faults

Malfunction
The unit performance is not satisfactory
UVC lamp display is not lit
No water outlet from the pond inlet
14833-08-13_GA_BioPress 4000-10015 15
Cause
Unit has been in operation only for a short time
Water extremely soiled
Excessive fish and animal population
Foam filters soiled
Quartz glass tube soiled
UVC lamp capacity exhausted
Power supply of Filtoclear-UVC not connected
UVC lamp defective
Connection defective
UVC overheated
Pump power supply not connected
Pond inlet blocked
Filter container/pump housing clogged
- GB -
Remedy
The complete biological cleaning effect is only
achieved after several weeks
Remove algae and leaves from the pond,
change the water
Guide value: approx. 60 cm fish length in 1 m³3
pond water
Clean filters
Remove UVC and clean quartz glass
Replace the lamp after approx. 8,000 operating
hours
Connect UVC power plug
Replace the UVC lamp
Check electrical connection
UVC automatically switches on when cooled
down
Connect pump power supply
Clean pond inlet
Clean filter container/pump housing