Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - EINHELL BG-WW 1136 Originalbetriebsanleitung

Hauswasserwerk
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung_BG_WW_1136_SPK7:_

14. Troubleshooting

Faults
The motor does not start up
Pump fails to prime
Insufficient pumping rate
Thermostat switches off the pump
Pump switches on and off too often - Leak in the water bag
21.07.2010
8:16 Uhr
Seite 15
Cause
- Power supply not connected
- Impeller blocked; the thermostat
has switched off
- Non-return valve dirty
- Pump housing without water
- Air in the intake line
- Max. intake height exceeded
- Intake height too high
- Coarse filter dirty
- Water level falling rapidly
- Pump performance reduced by
foreign bodies
- Motor overloaded, friction through
foreign bodies too high
- Pressure in the vessel is too low
GB
Remedy
Check power supply
- Dismantle the pump and clean
(by customer service workshop)
- Clean
- Fill water into the pump housing
- Check the proper sealing of the
intake line
- Check the intake height
- Check the intake height
- Clean
- Place the intake line at a deeper
level
- Clean the pump and replace wear
parts (by customer service
workshop)
- Dismantle the pump and clean,
prevent the intake of foreign
bodies (filter) (by customer
service workshop)
- Have the water bag replaced by a
customer service workshop
- Refill air into the vessel (see
11.1)
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis