Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Guide - EINHELL 41.705.17 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 41.705.17:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Anleitung_BG_DP_6015_N_SPK1:_

10. Troubleshooting guide

Faults
The equipment does not start
The equipment does not pump
The equipment does not cut out
Insufficient pumping rate
The equipment switches off after
briefly running
12.06.2008
15:33 Uhr
Cause
- Power supply not connected
- Floating switch does trigger
- Intake sieve clogged
- Discharge hose kinked
- Floating switch cannot sink
- Intake sieve clogged
- Performance reduced due to
heavily contaminated and
abrasive water impurities
- Motor circuit-breaker switches
the equipment off due to
excessive water contamination
- Water temperature too high;
motor circuit-breaker switches
the equipment off
Seite 11
Remedy
- Check power supply
- Raise position of floating switch
- Clean intake sieve with water jet
- Unkink the hose
- Place equipment correctly on
shaft bottom
- Clean intake sieve
- Clean equipment and replace
wear parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum
permissible water temperature
(35 °C) is not exceeded
GB
11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bg-dp 6015 n

Inhaltsverzeichnis