►►►12. TROUBLESHOOTING
FUNCTIONING
ANOMALIES
The motor does not
start
The flame does not
ignite
The flame does not
stay on
Flame goes out during
functioning
CAUSES
No power supply (if mains
powered)
Battery low (if battery-
powered)
Defective power supply or
battery
Faulty motor
Gas cylinder empty
Regulator safety valve
blocked
Gas cylinder cock closed
Faulty ignition circuit
Gas button not pressed for
long enough
Defective heater
Insufficient gas supply
The heater overheats
Defective heater
SOLUTION
1.Check the mains system
2.After-sales assistance
1.Charge the battery
2.After-sales assistance
After-sales assistance
After-sales assistance
Replace the gas cylinder (Par. 5)
1.Press the regulator gas release button
(Fig. 13)
2.After-sales assistance
Open the gas cylinder cock (Fig. 12)
After-sales assistance
Press the gas button for longer (Par.
7.1.5.)
After-sales assistance
1.Replace the gas cylinder (Par. 5)
2.After-sales assistance
1.Clean the air vent (rear side)
2.After-sales assistance
After-sales assistance