9. Disposal
a) General
Dispose of the obsolete appliance according to the valid legal direc-
tives.
Batteries and Accumulators
You are required by law to return all spent batteries/accumulators
(Battery Ordinance). Disposing of spent batteries/accumulators
in the household waste is prohibited!
Batteries/accumulators that contain hazardous sub-
stances are marked with the symbols on the side.
These symbols indicate that it is prohibited to dispose
of these batteries/accumulators in the household
waste. The abbreviations for the respective heavy met-
al are: Cd=Cadmium, Hg=Mercury, Pb=Lead (is indi-
cated on the battery/accumulator, e.g. underneath the
garbage can icons on the left).
You can return spent batteries respectively accumula-
tors free of charge to the collection points in your com-
munity, our outlets or everywhere else where batteries
or accumulators are sold.
You thus fulfil the legal requirements and contribute to the protec-
tion of our environment!
24
The outdoor sensor ASH555 can also be operated outside in a tem-
perature range from -30°C to +70°C at a maximum air humidity of
95%. Observe the instructions with respect to the installation site
under all circumstances!

2. Delivery Scope

• Outdoor sensor ASH555 with wall mount
• Operating manual
3. Features & Technical Data
• Temperature range . . . . . . . . . . . . -30°C to +70°C
• Humidity range . . . . . . . . . . . . . . . 5% up to 95% rel. humidity
• Frequency: . . . . . . . . . . . . . . . . . . 868.35 MHz
• Range: . . . . . . . . . . . . . . . . . . . . . . up to 100m (free space)
• Measuring/transmission cycle: . . . 3 minutes
• Power supply: . . . . . . . . . . . . . . . . 2 * mignon cells (AA, alkaline
• Dimensions: . . . . . . . . . . . . . . . . . Diameter 54 mm, height
Scale 0.1°C
Accuracy ±0.8°C
Resolution: 0.1%
Accuracy ±5%
recommended)
125 mm
Distance outdoor sensor to
installation site 70 mm