Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT VC731 Bedienungsanleitung Seite 77

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Resistance measurement / continuity / diode test
VC731 and VC732
Measuring type
Resistance
Continuity
Diode
Max. test current 0.5 mA
Max. voltage for resistance 3 V
Max. voltage for diode test ±1.8 V
Capacity
VC731 and VC732
Range
3.999 µF
39.99 µF
399.9 µF
3999 µF
Temperature
VC731
Measuring type
°C
°F
The above measured values are stable ±1 °C when the measuring prod was connected at
least 1 hour before. The measuring device requires 2 hours to stabilise.
Range
999.9 Ω
9.999 kΩ
99.99 kΩ
999.9 Ω
0.40 – 0.80 V
Accuracy
±2.7 % +12 dgt
Range
-50 – +99.9 °C
+100 – +399.9 °C
+400 – +1000 °C
-58 – +751.9 °F
+212.0 – +751.9 °F
+752 – +1832 °F
Accuracy
±1.43 % +7 dgt
±1.43 % +5 dgt
±1.43 % +7 dgt
±0.14 V
Accuracy
±1.43 % +3 °C
±1.43 % +1.5 °C
±1.43 % +5.7 °F
±1.43 % +2.9 °F
77

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vc732

Inhaltsverzeichnis