Herunterladen Inhalt Inhalt Diese Seite drucken

Delivery Content; Safety Instructions - VOLTCRAFT BS-25 Bedienungsanleitung

Endoskop
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OpERATING INSTRUcTIONS
BS-25 ENDOScOpE
ITEm NO.: 12 33 22
INTENDED USE
The endoscope is a visual aid for optical troubleshooting and inspection at powered-down
systems and facilities The camera image is displayed on the integrated TFT monitor, and the
lighting in the tip of the camera can be controlled. A PAL video output is available. The swan
neck camera is water-tight and suitable for use in watery liquids (no acids or lye). The basic
device must not be exposed to humidity or submersed. Power is supplied via four AA batteries
(not included). Operation in explosive atmospheres or use with persons and animals is not
permissible.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you
use the product for purposes other than those described above, the product may be damaged.
In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc.
Read the instructions carefully and keep them. Make this product available to third parties only
together with its operating instructions.

DELIVERy cONTENT

Endoscope
Carry box
Video cable
3 x attachments (magnet, hook, mirror)
Operating instructions

SAfETy INSTRUcTIONS

Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the warranty/
guarantee.
a)
persons / product
The device is a precision tool. Do not drop it and do not subject it to any impacts.
The basic device is not water-tight and therefore cannot be used underwater.
The endoscope must only be used for inspection in powered-down systems. The
camera head is made of metal and can lead to short-circuit.
For reasons of safety, power down all system parts before any inspection.
Always store the endoscope and its accessories in the case when not using them.
Sensitive surfaces (with furniture polish, etc.) may cause chemical reactions with
the casing.
Avoid strong mechanic stress or vibration.
Keep the device out of reach of children. It is not a toy.
Do not leave packaging material unattended. This could become a dangerous toy
in the hands of children.
On industrial sites, the accident prevention regulations of the association of the
industrial workers' society for electrical equipment and utilities must be followed.
If you have reason to believe that the device can no longer be operated safely,
disconnect it immediately and make sure it is not unintentionally operated. It must
be assumed that safe operation is no longer possible if:
-
the device shows visible damage
-
the device no longer works and
-
the device has been stored for long periods of time under unfavourable conditions
or
-
the device has been subjected to heavy stress during transport.
Never switch on the device immediately after it has been taken from a cold to a
warm environment. Under adverse conditions, the resulting condensation could
destroy the device. Allow the device to reach room temperature before switching
it on.
Observe also the additional safety instructions in each chapter of these operating
instructions as well as in the operating instructions of the connected devices.
b)
(Rechargeable) batteries
Correct polarity must be observed while inserting the (rechargeable) batteries.
(Rechargeable) batteries should be removed from the device if it is not used
for a long period of time to avoid damage through leaking. Leaking or damaged
(rechargeable) batteries might cause acid burns when in contact with skin, therefore
use suitable protective gloves to handle corrupted (rechargeable) batteries.
(Rechargeable) batteries must be kept out of reach of children. Do not leave
(rechargeable) batteries lying around, as there is risk, that children or pets swallow
VERSION 05/11
them.
All (rechargeable) batteries should be replaced at the same time. Mixing old and
new (rechargeable) batteries in the device can lead to (rechargeable) battery
leakage and device damage.
(Rechargeable) batteries must not be dismantled, short-circuited or thrown into fire.
Never recharge non-rechargeable batteries. There is a risk of explosion!
c)
miscellaneous
Consult an expert when in doubt about operation, safety or connection of the
device.
Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical support
or another qualified specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.
OpERATING ELEmENTS
10
9
8
INSERTING / REpLAcING BATTERIES
1.
Loosen the screw using a Phillips screwdriver and take off the cover of the battery
compartment.
2.
Remove the battery holder from the battery compartment.
3.
Insert four AA batteries into the battery holder, observing the polarity markings
inside the battery holder bays.
4.
Put the battery holder back into the battery compartment, observing the polarity
markings on the top of the battery holder and inside the battery compartment.
5.
Close the battery compartment again.
Replace the batteries when the battery LED is on.
1
2
1.
Goose neck
3
2.
Ring bolt
4
5
3.
Power LED
4.
Battery LED
5.
Video output
6.
Button ↑
6
7.
Battery compartment
8.
Button on/off
9.
Button ↓
10.
Monitor
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis