  • DEUTSCH, seite 1
Fault
Pump stops, two pairs
of lights blink, alter-
nating sides.
Pump stops intermit-
tently and turns back
on. After several cy-
cles, two pairs of lights
blink, alternating sides
Pump transports is re-
ducing or transported
quantity is too low
Our Kärcher branch will be pleased to help you further in the case of questions or faults.
See address on the reverse.
22
Cause
Failure in the pressure
line, flow too small, the
pump frequently
switches on and off as
a result of reduced wa-
ter extraction.
Failure in the pressure
line, the pump fre-
quently switches on
and off as a result of
leakage.
Pressure loss due to
missing or defective
backflow valve
Pressure reduction by
leakages in the system
Suction pipe blocked
Pre-filter is dirty
Suction side is leaky
The quantity transport-
ed by the pump de-
pends on the transport
height and the connect-
ed periphery
EN
Remedy
If reduced water extraction is required, the
switching frequency can be reduced by in-
creasing the overpump time, and thus the
occurrence of this failure can be avoided.
Restart the pump by continuously press-
ing the - button.
Check and correct the pressure line for
leakages (dripping water tap).
Restart the pump by continuously press-
ing the - button.
Ensure that the backflow valve is correctly
inserted into the fill neck.
Observe the care instructions.
Check all connection locations on the suc-
tion and pressure sides as well as all the
lids for tightness.
Install a pressure compensating hose on
the pressure side (see special accesso-
ries). As an alternative, a pressure com-
pensating container can be installed as a
pressure tank.
Pull out the mains plug and clean the suc-
tion pipe
Remove the prefilter and the backflow
valve and clean them under flowing water,
rinse any dirt residues from the fill neck by
opening the discharge opening.
Check the entire suction side for leaks
Keep max. flow height, see technical data.
If necessary, select a different hose diam-
eter or hose length.
– 8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading