AC Current
Range
Resolution
2mA
1µA
200mA
0.1mA
20A
10mA
Resistance
Range
Resolution
200
0.1
2k
1
20k
10
2M
1k
20M
10k
Capacitance
Range
2nF
200nF
100µF
Temperature
Range
O
C
Accuracy
±(1.0%+3)
±(1.8%+3)
±(3.0%+5)
Accuracy
±(0.8%+3) + Test Lead
Short Circuit Resistence
±(0.8%+1)
±(1.0%+2)
Resolution
1pF
0.1nF
0.1µF
±(5.0%+4) When it is > 40µF: the
obtained reading is only for reference
Resolution
O
1
C
4
Tabels
Overload
Protection
CE Version: Fuse 0.5A,
250V, fast type, 5x20mm
Overload
Protection
250V AC
Accuracy
±(4.0%+3)
Accuracy
O
-40~0
C ± (3%+7)
O
0~400
C ± (1%+3)
O
400~1000
C ± 2.5%