Herunterladen Inhalt Inhalt Diese Seite drucken

Function / Operation - STEINEL IS 3360 MX DALI Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für IS 3360 MX DALI:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion detection into
consideration.
Procedure for installing concealed power supply lead (Fig� 5�1)
Procedure for installing surface-mounted power supply lead (Fig� 5�2)
IS 3360 DALI, IS 3360 MX Highbay DALI, IS 345 DALI, IS 345 Highbay DALI
Procedure for installing concealed power supply lead (wall mounting)
IS 3180 DALI (Fig� 5�3)
• Switch OFF power supply�
• Detach designer trim from sensor module.
• Disconnect sensor module from the load module.
• Connect to mains power supply.
– Surface-mounted power supply lead (Fig� 5�4)
– Concealed power supply lead (Fig� 5�5)
• Insert fastening screws and mount load module.
Limiting reach
The detection zone can be optimised to suit requirements.
– By adjusting the lens. (Fig� 5�8 / 5�10)
– By using the half-round clip-on shroud. (Fig� 5�11)
Note: to limit reach, the sensor module must be detached from the load module.
• To set the required reach, undo the screws or completely remove them.
• Move lens into required zone.
• The half-round clip-on shroud provided can be used for masking out any number of
lens segments to shorten reach as required.
• Afterwards, fix the lens in place with the screws.
Detection zone / reach
IS 3360 DALI (Fig� 5�6)
IS 345 DALI (Fig� 5�8)
IS 3360 MX (Fig� 5�7)
IS 345 MX DALI (Fig� 5�9)
Mounting height
Mounting height
Reach
14 m
10 m
9 m
14 m
6 m
16 m
2.8 m
18 m
Reach
14 m
30 m × 4
10 m
25 m × 4
8 m
20 m × 4
6 m
15 m × 4
4 m
10 m × 4
28
IS 3180 DALI (Fig� 5�10)
Mounting
20 m lens
height
Setting level tangential
1.5 m
8
5 m
6 m
7 m
8 m
20
12 m
2.0 m
8
5 m
6 m
7 m
10 m
20
20 m
2.5 m
8
6 m
8 m
10 m
13 m
20
20 m
3.0 m
8
8 m
9 m
12 m
17 m
20
20 m
Note: the factory setting is 20 metres
• Fit sensor and load module together and screw into place.
• Switch ON power supply�
• Set functions. (➔ "6� Funtion")
• Fit designer trim.
6� Function / operation
Factory settings
Twilight setting: daytime mode
Time setting: 5 s
Main light: 80%
Twilight setting (Fig� 6�1)
The chosen sensor response threshold is infinitely adjustable from approx. 2-1000 lux.
Control dial set to
means twilight mode at approx. 2 lux.
Control dial set to
means daylight operation / independent of ambient light level.
Teach mode
The control must be set to
at the level of light at which you want the sensor to
respond to movement from now on. The level of ambient brightness measured in this
way will be saved after 10 seconds.
8 m lens
radial
Setting level tangential
radial
2.5 m
4
3 m
2.5 m
5 m
3.0 m
6 m
3.0 m
7 m
4.5 m
8
9 m
2.5 m
4
4 m
3.0 m
5 m
3.5 m
6 m
4.0 m
8 m
4.5 m
8
8 m
3.0 m
4
5 m
4.0 m
7 m
5.0 m
8 m
5.0 m
9 m
4.0 m
8
10 m
4.0 m
4
5 m
4.5 m
6 m
5.0 m
8 m
4.0 m
10 m
4.0 m
8
13 m
29
2.0 m
2.5 m
3.0 m
3.0 m
3.5 m
3.0 m
3.0 m
3.0 m
3.0 m
3.5 m
3.0 m
3.5 m
3.5 m
4.0 m
3.5 m
3.0 m
3.0 m
4.0 m
4.5 m
5.5 m

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis