Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Work - Mitsubishi Electric MLZ-KA25VA Bedienungsanleitung

Ceiling cassette type air conditioners
Vorschau ausblenden Andere Handbücher für MLZ-KA25VA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
This dries the inside of the unit.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter.
Page 6
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
S
PECIFICATIONS
Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
Input
Weight
Indoor
IP code
Indoor
LP ps
Permissible excessive
operating pressure
HP ps
Noise level
Indoor (High/Med./Low) dB(A)
Page 4
MLZ-KA25VA
Cooling
Heating
kW
kW
0.040
0.040
kg
MPa
MPa
35/32/29
36/32/28
I
NSTALLATION PLACE AND

ELECTRICAL WORK

Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
Inverter-type
To prevent the effects
fl uorescent lamp
of a fl uorescent lamp,
keep as far apart as
possible.
Keep a space to
prevent the pic-
ture distortion or
1 m
the noise.
or more
1 m
TV
or more
Cordless
phone or
Portable
phone
Radio
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
MLZ-KA35VA
Cooling
Heating
~/N, 230 V, 50 Hz
0.040
0.040
15
IP20
1.64
4.15
37/34/31
38/35/31
Note:
1. Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
2. This indoor model is only for multi system air conditioner.
As for the specifi cations of multi system, please confi rm your dealer
and/or refer to the catalogue.
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
wall, etc.
Well-
ventilated dry
place
3 m or
more
MLZ-KA50VA
Cooling
Heating
0.040
0.040
43/38/34
43/39/34
En-8

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mlz-ka35vaMlz-ka50va

Inhaltsverzeichnis