1. Unscrew the water infill screw.
2. Pour water into the infill opening until it
overflows.
3. Screw in the water infill screw again.
4. Open the pressure line if necessary.
5. Insert the power plug into the socket.
6. Switch on the pump.
– The pump starts pumping immedi-
ately. The emerging water still con-
tains some air.
Shutting down the pump
How to proceed:
1. Switch off the pump
2. Disconnect the power plug.

REMEDY OF FAULTS

The following warning information applies to all work. Exceptions are marked with .
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocution.
Prior to starting work:
• Switch off the unit, disconnect the power plug and secure the unit from being switched
on again.
• Before stepping into or reaching into the water, switch off all units located in the water.
On completion of the work:
• Restore all the prerequisites for start-up.
Malfunction
Pump does not start.
Pump switches off after a
short running period.
12
3. Depressurise the pressure line by open-
ing the water withdrawal points.
4. Also open any non-return valves fitted in
the suction line.
– When the pump is switched off, resid-
If the pump is to be completely removed:
 D
5. Remove the connected hoses on the
pressure and suction side.
6. Undo the water drain screw and tip the
pump to allow the residual water to drain
out.
7. Screw in the water drain screw again.
– Check that the seal is in place and
Cause
The pump is switched off.
Power supply interrupted
The fault current protection
device has tripped.
Overload protection has
switched the pump off due
to overheating.
ual water in the hose may flow back
and out of the pump intake.
correctly functioning.
Remedy
Switch on the pump.
Check the electrical plug
connections.
Switch off the pump and
disconnect the power plug.
Then contact the OASE
Service.
• Clean the connection on
the suction side and the
suction line.
• Allow the pump to cool
down.
ProMax Garden Classic 3000/4500