Herunterladen Inhalt Inhalt Diese Seite drucken

Sharp XV-Z9000U Serviceanleitung Seite 46

Vorschau ausblenden Andere Handbücher für XV-Z9000U:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

XV-Z9000U/E
No horizontal
synchronization
Is the terminal input
connection as specified? Is
the cable tightly
connected?
NO
Is there the horizontal sync
pulse at pin (14) of
IC2506?
YES
Is there the horizontal
sync pulse at pin (11) of
IC2509?
YES
Go to "PC Board
Troubleshooting".
No vertical
synchronization
Is the terminal input
connection as specified? Is
the cable tightly
connected?
NO
Is there the vertical sync
pulse at pin (14) of
IC2501?
YES
Is there the vertical sync
pulse at pin (8) of
IC2509?
YES
Go to "PC Board
Troubleshooting".
YES
Use the specified cable.
Reconnect it tight enough.
NO
Check the line between
IC2506 and the input
terminal.
NO
Check the line between
IC2506 and IC2509.
YES
Use the specified cable.
Reconnect it tight enough.
NO
Check the line between
IC2501 and the input
terminal.
NO
Check the line between
IC2506 and IC2509.
46

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xv-z9000e

Inhaltsverzeichnis