Certificates and approvals
Classification according to the pressure
equipment directive
(DGRL 97/23/EC)
Dimension drawings of the electrical connections
M12x1 / Fixcon
SITRANS P210, type 7MF1566
Additional notes on installation
The following conditions relating to types
7MF1566-***01-1**1
7MF1566-***01-2**1
must be met:
Operation is permitted only when connected to certified intrinsically-safe resistive
circuits with the following maximum values:
U
< 30 V
i
I
ª
< 100 mA
i
P
ª
< 750 mW
i
Internal inductance L
Internal capacitance C
A maximum ambient air temperature T
Use as a resource belonging to category 1/2:
The pressure transmitters can be mounted in the wall separating the area with category 1 requirements (zone 0) and the area with category 2 requirements (zone 1).
In this case, the process connection must be adequately sealed in compliance with EN 60079-26, clause 4.6, for example by providing degree of protection IP67 in
compliance with EN 60529. The supply must be via intrinsically safe circuits with type of protection ia. The measuring cell may only be used for flammable materials
to which the diaphragms of the measuring cells are adequately resistant both chemically and in terms of corrosion.
The date of manufacture can be seen on the label of the pressure transmitter, for example: LKK-YMDD-XXX-XX-XXX
(1)
Decoding for year, month and day information
Code
(2)
A
B
C
D
Calendar year 2010
2011
2012
2013
Code
(2)
1
2
3
Month
January February March
April
Code
01 - 31
Day of month 1st to 31st day
Technical support
You can contact Technical Support for all IA and DT products:
Via the Internet with the support request: www.siemens.com/automation/support-request
E-mail: support.automation@siemens.com
Phone: +49 (911) 895 7 222
Fax: +49 (911) 895 7 223
Further information about our technical support is available on the Internet at www.siemens.com/automation/csi/service
For gases of fluid group 1 and
liquids of fluid group 1; fulfills
the requirements according to
article 3, paragraph 3 (good
engineering practice)
36
M16x1.5
or
1/2-14 NPT
± 24
7MF1566-***01-5**1
= 0 nH
i
= 0 nF
i
of -25 to +85 ÀC is permitted for the pressure transmitter.
a
Manufacturer's abbreviation
(1)
Date as "year-month-day„
3 digits of the order number
Order position
Single part number
Separator
I
F
H (G)
(3)
J
K
L
2014
2015
2016
2017
2018 2019
4
5
6
7
8
May
June
July
August
September
Protection against explosion 7MF1566-xxxx1-xxxx
Intrinsic safety "i" (with current
output only)
EC type examination certificate
Connection to certified intrinsi-
cally safe resistive circuits with
maximum values
Effective internal inductance and
capacitance for versions with plugs
complying with EN 175301-803-A
and M12
Dimension drawings of the process connections
7/16„-20 UNF
M
N
P
R
S
2020 2021
2022
2023
2024
2025 2026
9
O
N
D
October
November
December
2)
Agreement with DIN EN 60062
3)
The letter G is not permitted for new applications since it deviates from
DIN EN 60062. It serves only for coding back.
II 1/2 G Ex ia IIC T4 Ga/Gb
II 1/2 D Ex ia IIIC T125ÀC Da/Db
SEV 10 ATEX 0146
U
< 30 VDC; I
i
L
= 0 nH; C
= 0 nF
i
i
max. 30 Nm
max. 20 Nm
max. 20 Nm
max. 20 Nm
T
U
V
W
X
2027
2028 2029
< 100 mA; P
< 0.75 W
i
i
G1/2„
SITRANS P210 (7MF1566)