Please Read Immediately; Important Notes; Intended Use; Legal Regulations And Guidelines - Dimplex HPL 6S-TUW Montage- Und Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für HPL 6S-TUW:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
1
Please read
immediately

1.1 Important notes

ATTENTION!
When operating or maintaining a heat pump, the legal requirements of the
country where the heat pump is operated apply. Depending on the
refrigerant fill quantity, the heat pump must be inspected for leaks at
regular intervals by a certified technician, and these inspections must be
recorded.
ATTENTION!
When transporting the heat pump, ensure that it is not tilted more than
45° (in any direction).
ATTENTION!
Do not restrict or block the area around the air intake or outlet.
ATTENTION!
Observe country-specific building regulations!
ATTENTION!
For installation close to walls the physical influences of the building must
be considered. No windows or doors should be present in the area
surrounding the air outlet of the ventilator.
ATTENTION!
In cases of installation close to a wall, there may be more sediment in the
air inlet and outlet areas due to the air current. The colder outside air
outlet should discharge in such a way as to not increase the heat losses
in heated neighbouring rooms.
ATTENTION!
Installation in a hollow or in an inner courtyard is not permitted because
cooled air collects at ground level and is drawn in again by the heat pump
during lengthy operation.
ATTENTION!
The frost line can vary according to the climatic region. The regulations
of the countries in question must be observed.
ATTENTION!
With fully demineralized water, it is important to ensure that the minimum
permissible pH value of 7.5 (minimum permissible value for copper) is
complied with. Failure to comply with this value can result in the heat
pump being destroyed.
ATTENTION!
Ensure the rotary field is clockwise when connecting the mains cables (if
the rotary field is not clockwise, the heat pump will not work properly, is
very loud and may cause damage to the compressor).
ATTENTION!
The communication cable is necessary for the function of air-to-water
heat pumps in outdoor installation. It must be shielded and laid
separately from the mains cable
ATTENTION!
Operating the heat pump at low system temperatures may cause the heat
pump to break down completely.
EN-2
ATTENTION!
Before opening the device, ensure that all circuits are disconnected from
the power supply!
ATTENTION!
Work on the heat pump must only be performed by authorised and
qualified after-sales service technicians!

1.2 Intended use

This device is only intended for use as specified by the manufac-
turer. Any other use beyond that intended by the manufacturer is
prohibited. This requires the user to abide by the relevant project
planning documents. Please refrain from tampering with or alter-
ing the device.
1.3 Legal regulations and
This heat pump is designed for use in a domestic environment
according to Article 1, Paragraph 2 k) of EC directive 2006/42/EC
(machinery directive) and is thus subject to the requirements of
EC directive 2006/95/EC (low-voltage directive). It is thus also in-
tended for use by non-professionals for heating shops, offices
and other similar working environments, agricultural establish-
ments and hotels, guesthouses and other residential buildings.
The construction and design of the heat pump complies with all
relevant EU directives, DIN/VDE regulations (see CE declaration
of conformity).
When connecting the heat pump to the power supply, the rele-
vant VDE, EN and IEC standards are to be adhered to. Any fur-
ther connection requirements stipulated by the mains supply net-
work operator must also be observed.
When connecting the heating system, all applicable regulations
must also be adhered to.
Persons, especially children, who are not capable of operating
the device safely due to their physical, sensory or mental abilities
or due to their inexperience or lack of knowledge, must not oper-
ate this device without supervision or instruction by the person in
charge.
Children must be supervised to ensure that they do not play with
the device.
ATTENTION!
When operating or maintaining a heat pump, the legal requirements of the
country where the heat pump is operated apply. Depending on the
refrigerant fill quantity, the heat pump must be inspected for leaks at
regular intervals by a certified technician, and these inspections must be
recorded.
More information can be found in the accompanying log book.
452163.66.68 · FD 9705
guidelines
HPL 6S-TU(R)W
www.dimplex.de