Output control
Certain experience is required for output control because it depends on a number of factors, such
as negative pressure inside the chimney (draught) and fuel quality. Therefore, read carefully these
instructions to learn how to operate your fireplace to achieve the best performance.
The output is controlled by means of the primary air supply control device on the fireplace door.
Secondary air supply is provided above the door glazing and it is sufficient for air-washing of the
glass
The fireplace output also depends on the draught inside the chimney. In case of excessive
draught, it is recommended to reduce it by means of the fluepipe damper.
Certain experience is also required for the proper setup of the air supply control device. Therefore,
follow our advice to learn easily how to operate your fireplace.
Setting up the air supply control for starting the fire and for some time thereafter
When the fire has blazed up and sufficient ember bed has been created, set the air supply control
back to the position ensuring the air supply that is sufficient for the fireplace to develop as much
heat as required.
By adding 3 - 4 kg of the fuel and keeping the air supply control set to maximum output, the
fireplace will reach 11-12 kW.
Setting up the air supply control for rated output of 8 kW
To operate the fireplace at the minimum output, set the primary air supply control to fully closed
position. If you have a fluepipe damper installed, close the damper as well.
Make sure to add only as much fuel as it is necessary to maintain the fire.