to take the chosen covering model into consideration.
The positioning is implemented according to the model chosen
(refer to the installation instructions found inside the packaging
tion process.
intake and connect the air adjustment mechanism to the hole as
described in the chapter called "external air inlet".
- Verify that all moving parts function properly before setting
- This system must be tested and ignited for the rst time
before the covering is set in place.
INSTALLATION COVERING, FIREPLACE MAN-
TEL AND VENTILATION OUTLETS
internal air to be recycled. Therefore, suitable slots or apertures
must be made for the air to pass through. Parts of the thermo
place so as to prevent possible breakage due to expansion and
excessive overheating.
Practical advice
It is recommended to keep the radiators closed in the room
- An incomplete combustion process causes excessive fouling
on the heat exchanger pipe.
- burn dry wood.
- ensure the hearth contains a bed of embers and burning car-
bon before adding more wood.
- place larger logs together with smaller ones.
- make sure the temperature of the return water is at least 50 °C
(use temperature control valve).
Igniting the replace
- Ensure that at least one radiator is always open.
- Actuate the switches of the electronic regulator.
- Close the door
- Set the thermostat on the electronic regulator (*) at a tempera-
ture between 50 and 70° C.
it is ignited, however, this will disappear quickly.
(*) these components of the system are to be provided by the installer.
INSTALLATION
-
-
-
-
INSTRUCTIONS FOR USE
- 26
must be an appropriate distance of at least 1 cm to allow the
between the door and the beam). Through convective motion,
in heat recovery and preventing excessive overheating.
In addition to that mentioned above, please consider the in-
dications stipulated in the UNI 10683 standard, paragraphs
4.4 and 4. : "insulation, nishing, replace covering and
safety recommendations".
Insulating mats must be applied when using an installation
KIT so as to protect it from the heat radiation emitted by
the thermo replace.
INLET FRAME (OPTIONAL)
To facilitate coupling with the covering's components, the ther-
front of the inlet.
A
3-way valve
when the set temperature is reached, the 3- way valve (*)
installed).
By-pass damper
- When the door is closed, the by-pass damper automatically
- When the door is opened, the damper bypass opens automa-
preventing it from coming out of the inlet.
Thermal Relief Valve
If the water temperature exceeds 90° C (e.g. because of too
much wood being placed in the hearth) the thermal relief valve
will be activated and the acoustic signal triggered.
Do not load additional fuel and wait for the temperature to fall
below 80°C checking the warning lights on the electronic regu-
lator. The hot water tap can be opened to speed up the cooling
water production KIT.
-