Fault
Warning signal sounds.
Temperature display flashes.
Fig. "/2
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Appliance is not cooling,
temperature display, Fig. "/
2, is lit.
38
Possible cause
Fault - the freezer
compartment is too warm!
Frozen food is at risk.
Appliance is open.
Ventilation openings have
been covered.
Too much food was placed in
the freezer at once.
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Showroom mode is switched
on.
Remedial action
To switch off the warning signal, press the
temperature setting button, Fig. "/4.
Close the appliance.
Ensure that there is adequate ventilation.
Do not exceed max. freezing capacity.
When the fault has been rectified, the
temperature display stops flashing.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. +
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Hold down temperature setting button,
Fig. "/4, for 10 seconds until an
acknowledgement signal sounds.
After a short time check whether your
appliance is cooling.